Fire Department

Training Report
Live Fire Instructor Course — NFPA 1403 (Interactive)
Hours
3
ISO Category
Officer
Equipment
Device with a browser or a classroom projector; the department's current live fire SOP and pre-burn plan template for the plan audit

Instructor-side live fire course covering NFPA 1403, the controlling standard for every live fire evolution. Students take a live fire class; the people responsible for students take this one. Department-neutral on facility on purpose — covers BOTH a fixed burn prop and an acquired structure, which carries a separate and much longer list of 1403 requirements (owner permission and title, insurance, permits, asbestos survey, utilities disconnected, tanks removed, exposures protected). Also covers the written pre-burn plan and why a blank section stops the burn; Class A fuel limits and the absolute prohibition on accelerants; two independent water sources with duration and reserve, and why two lines off one hydrant is a single source; every required position and the Safety Officer's authority to halt regardless of rank; real working air versus the label on the bottle; NFPA 1584 rehab criteria; the stop-condition list; and the records that must be retained. 8 modules, a knowledge check on each, 25-question final at 80%. Interactive course: livefire.pcfdmembers.org

  1. State that NFPA 1403 is the controlling standard and that a department SOP falling below it is a defect in the SOP.
  2. List what a written pre-burn plan must contain and recognise that a blank required section stops the burn.
  3. Distinguish fixed-prop requirements from the additional requirements for an acquired structure.
  4. State the fuel rules — Class A ordinary combustibles in a known quantity, no accelerants at any time.
  5. Explain why two lines off one hydrant is a single water source and identify a compliant second source.
  6. Identify every required position and state that the Safety Officer may halt any evolution regardless of rank.
  7. Apply real air-management figures rather than the rating on the cylinder.
  8. State the NFPA 1584 criteria that hold a member out of an evolution.
  9. List the conditions that mean you do not light, or that kill a set already burning.
  10. Identify the records that must be retained after a burn.
NameRankGFSTC #Signature
NameRankGFSTC #Signature

Firefighters from other departments. Add each person by hand, then tap to sign.

NameDepartmentRankGFSTC #Signature
EquipmentDamagedComments
Punctual · Valuable · Selfless

Submitted

Stop — Check Your Work

Tick every box to confirm. PDF will not download until all 7 are checked.
Please check after yourself before downloading. If anything below is not done, go back and fix it before you submit.
  • Time is entered correctly in 24-hour format (e.g. 0800, 1330).
  • Hours are whole numbers only — NO .5. Use 3, 4, 8 — not 3.5.
  • Description and objectives are filled out correctly.
  • All personnel participating have signed.
  • Driver Training: If personnel did NOT drive, they do NOT sign — they need an Area Familiarization sign-in instead.
  • Facility training is 3 hours or more AND held at the training facility.
  • Reviewed everything above. Questions? Call Dorman BEFORE submitting.
0 of 7 confirmed

Sign Here